Description
Patient Monitor YR02175 is a versatile, state-of-the-art modular parameter monitor designed for use in Operating Theatres (OT) and Intensive Care Units (ICU). With its 12.1-inch LCD screen, it offers clear and precise readings of essential patient parameters including ECG, SPO2, NIBP, RESP, PR/HR, and TEMP. The monitor’s standard configuration includes a 5-lead ECG, dual temperature readings, and non-invasive blood pressure measurement, making it an invaluable tool in critical patient care. This advanced device ensures accurate monitoring and facilitates prompt medical response, helping enhance patient safety and care efficiency. Explore the potential of the Patient Monitor YR02175 by generating an automatic quotation via Kalstein Plus today.
Market Price
When considering the purchase of a patient monitor like the Patient Monitor YR02175, it’s important to note that these devices typically range in price from approximately $3,900 to $4,700 USD in the market. This investment reflects the advanced technology and essential features that such monitors provide, ensuring comprehensive patient monitoring.
Frequently Asked Questions
Q: Is the Patient Monitor YR02175 suitable for neonatal and pediatric use?
A: Yes, the monitor includes parameter settings for neonatal and pediatric patients, with appropriate heart rate and respiration ranges.
Q: Does the monitor provide audible alarms?
A: Yes, it is equipped with an audio-video alarm system to alert medical professionals to any critical changes in patient status.
Advantages and Disadvantages
Advantages: The Patient Monitor YR02175 is reliable, versatile, and features a modular design that supports various clinical needs. Its clear display and comprehensive monitoring capabilities make it an excellent choice for critical care environments.
Disadvantages: While robust and feature-rich, this monitor may require specialized training to use effectively, especially for those unfamiliar with its advanced features.
Product Use in the Field
The Patient Monitor YR02175 is extensively utilized in both operating theatres and ICU settings. It provides continuous monitoring of vital signs, assisting healthcare providers in making timely decisions. The monitor’s adaptability to various patient groups, including adults, neonates, and children, enhances its applicability in diverse clinical scenarios.
Recommendations
To maximize the lifespan and accuracy of the Patient Monitor YR02175, regular maintenance and calibration are recommended. Ensure proper training for medical staff to fully leverage its comprehensive features. Regular software updates can also enhance its functionality.
Features
- 12.1 inch LCD screen for clear display
- Comprehensive monitoring parameters: ECG, SPO2, NIBP, RESP, PR/HR, TEMP
- 5-lead ECG with dual temperature readings
- Audio-video alarm system to notify of changes in patient condition
- Modular design suitable for OT and ICU
- Usable for adults, neonates, and pediatric patients
Technical Specifications
Model | YR02175 | |
ECG | Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Waveform | 1ch | |
Gain | x250, x500, x1000, x2000 | |
HR Range | Adult: 15~300bpm | |
Neo/Ped | 15~350bpm | |
Accuracy | ±1% or ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -2.0~+2.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate | Measuring range | 25~300bpm |
Accuracy | ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration | Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | >2.0MΩ | |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Base line Impedance Range | 200~4000Ω | |
Bandwidth | 0.1~2.5Hz | |
Resp. Rate | Adult: 2~120BrPM | |
Neo/Ped | 0~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
Alarm | 10~40S | |
NIBP | Method | Oscillometric |
Mode | Manual/Auto/STAT | |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
Accuracy | Maximum Mean error: 5mmHg | |
Maximum Standard deviation | 8mmHg | |
SPO2 | Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 60~100% (±2%) | |
Alarm system | Audio-video alarm | |
Pulse rate range | 0~300bpm | |
TEMP | Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | about 1 Second | |
Average Time Constant | <10 Second |