Description
The Doppler Fetal Monitor YR02180 is a highly sophisticated device designed for use in operating theaters and intensive care units. Equipped with a 17-inch LCD screen, this semi-modular monitor provides precise measures through its six standard parameters: ECG, SPO2, TEMP, NIBP, RESP, and PR/HR. With its advanced monitoring capabilities and optional features like a touchscreen and thermal recorder, it adapts to various medical needs, ensuring reliable results and enhanced patient care. This professional-grade monitor will not only elevate clinical assessments but also foster comprehensive patient monitoring with accuracy and ease.
Market Price
The pricing for advanced medical devices like the Doppler Fetal Monitor YR02180 is generally around $3,500 to $4,200 USD, reflecting its robust functionality and indispensable role in healthcare settings. This competitive range makes it accessible to a wide spectrum of medical practitioners who prioritize top-notch patient monitoring solutions.
Frequently Asked Questions
1. What are the standard parameters measured by this monitor?
The YR02180 measures ECG, SPO2, TEMP, NIBP, RESP, and PR/HR as standard parameters, providing comprehensive data.
2. Is there an option for data storage or export?
Yes, optional features include data storage solutions and connectivity for efficient data management.
Pros and Cons
Pros:
– Comprehensive monitoring with six standard parameters.
– Optional features for customization.
– High-resolution 17-inch LCD display for clear visuals.
Cons:
– Installation may require professional help due to complexity.
– Higher price point due to extensive features and capabilities.
Product Use in Field
This fetal monitor is pivotal in surgical and intensive care environments, where it supports critical patient assessments. Its multi-parameter monitoring ensures intricate data collection, enabling doctors and healthcare providers to make informed decisions swiftly.
Recommendations
Regular calibration and maintenance of the Doppler Fetal Monitor YR02180 are crucial for optimal performance. Healthcare providers should ensure it is operated by trained personnel to maximize its capabilities and longevity.
Features
– Large 17-inch LCD screen for better readability.
– Semi-modular design allows for easy integration of additional features.
– Measures multiple parameters including ECG and respiration with high accuracy.
– Optional touchscreen and thermal recorder available.
Technical Specifications
Model | YR02180 | |
ECG | Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Gain | x250, x500, x1000, x2000 | |
Accuracy | ±5% | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -1.0~+1.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate | Measuring range | 40~240bpm |
Accuracy | ±3bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration | Method | Impedance between R-F(RA-LL) |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 7~120BrPM | |
Neo/Ped | 7~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
NIBP | Method | Oscillometric |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm / 40~150bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
SPO2 | Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 70~99% (±2%) | |
Pulse rate range | 0~300bpm | |
TEMP | Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | about 1 Second. | |
Average Time Constant | <10 Second. |