Description
The Multi-parameter Patient Monitor YR02178 / YR02179 is an innovative solution designed for continuous monitoring of vital signs in critical environments such as operating theaters (OT) and intensive care units (ICU). Featuring a semi-modular design with a sleek LCD screen, this patient monitor supports standard parameters like ECG, SPO2, TEMP, NIBP, RESP, and PR/HR. For institutions aiming to enhance their medical capabilities, optional upgrades include a touch screen, advanced SpO2 technologies, and a variety of other customizable features.
Market Price
In the competitive landscape of medical devices, patient monitors can vary significantly in price depending on features and brand reputation. The YR02178 / YR02179 models, with their advanced functionalities, fall within a typical market price range of $3100 to $3900 USD. Interested buyers should assess their specific needs and budget to determine the best configuration for their facilities.
Frequently Asked Questions
Q: Can the monitor integrate with existing hospital systems?
A: Yes, the YR02178 / YR02179 models are designed to be compatible with most standard hospital systems and can be easily integrated.
Q: Are there any extended warranty options available?
A: Extended warranty options are available for these models. Please contact us for further details on the warranties and service plans.
Advantages and Disadvantages
The primary advantage of the YR02178 / YR02179 patient monitors is their flexibility and optional add-ons, allowing for tailored solutions. The high accuracy of readings and the intuitive design facilitate ease of use in high-pressure environments. However, the semi-modular nature may require significant initial investment, and novice users might need some training to utilize all features effectively.
Product Use in the Field
Designed for intensive care and operating settings, these monitors enable medical professionals to continuously observe patient vitals, ensuring quick response times to any change in patient status. The robust design stands up well to the demands of hospital use, providing reliability when it counts.
Recommendations
To maximize the YR02178 / YR02179 monitor’s lifespan, regular maintenance and calibration according to the manufacturer’s guidelines are essential. Training sessions for staff can enhance user proficiency, ensuring that all features are utilized to full effect. We recommend scheduling routine checks as part of a preventive maintenance plan.
Features
- Semi-modular design with optional touch screen
- Standard ECG, SPO2, TEMP, NIBP, RESP, PR/HR monitoring
- LCD display for clear visualization
- Optional advanced parameters like Dual-IBP and C.O.
- Customizable with thermal recorder, wall mount, or trolley
Technical Specifications
Model | YR02178 | YR02179 | |
ECG
|
Lead mode | 5 Leads(RA,LA,LL,RL,V) | |
Connection method | I, II, III,AVR,AVL,AVF,V | ||
Lead Mode | 3 Leads (RA,LA,LL) | ||
Connection method | I, II,III | ||
Waveform | 1ch | ||
Gain | x250, x500, x1000, x2000 | ||
HR Range | Adult: 15~300bpm | ||
Neo/Ped | 15~350bpm | ||
Accuracy | ±1% or ±1bpm | ||
Resolution | 1bpm | ||
Sensitivity | >200(uVp-p) | ||
Differential input impedance | ≥5MΩ | ||
ST segment Monitoring Range | |||
Measure Range | -2.0~+2.0mV | ||
Measure Accuracy | -0.8mV~+0.8mV | ||
Heart Rate
|
Measuring range | 40~240bpm | |
Accuracy | ±3bpm | ||
Resolution | 1bpm | ||
Sensitivity | >200UVp-p | ||
Respiration
|
Method | Impedance between R-F(RA-LL) | |
Differential Input Impedance | >2.5MΩ | ||
Measuring Impedance Range | 0.3~3.0 MΩ | ||
Base line Impedance Range | 200~4000Ω | ||
Bandwidth | 0.1~2.5Hz | ||
Respiration Rate | Adult: 7~120BrPM | ||
Neo/Ped | 7~150BrPM | ||
Resolution | 1 BrPM | ||
Accuracy | ±2 BrPM | ||
Alarm | 10~40S | ||
NIBP
|
Method | Oscillometric | |
Mode | Manual/Auto/STAT | ||
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | ||
Measuring Period in STAT Mode | 5 Min | ||
Pulse Rate Range | 40~240bpm | ||
Alarm Type | SYS, DIA, MEAN | ||
Resolution | |||
Pressure | 1mmHg | ||
Accuracy | Maximum Mean error: 5mmHg | ||
Maximum Standard deviation | 8mmHg | ||
SPO2
|
Display | Number of SPO2,waveform of capacity,Pulse | |
Measuring range | 0~100% | ||
Resolution | 1% | ||
Accuracy | 70~99% (±2%) | ||
Alarm system | Audio-video alarm | ||
Pulse rate range | 0~300bpm | ||
TEMP
|
Channel | 2 | |
Measuring and Alarm Range | 0~50ºC | ||
Resolution | 0.1ºC | ||
Accuracy | 0.1ºC | ||
Actualization interval | about 1 Second. | ||
Average Time Constant | <10 Second. |