The development of the current industry has led to the need for ever faster, more powerful and more accurate analytical tools that provide reliable and high-precision results. At present, turbidity measurement instruments are tools with technology, which work on the basis of optical phenomena that occur when a beam of light hits a medium. Turbidity is an optical property that results when light passes through a liquid sample and is dispersed by particles. The scattering of light results in a change in the direction of light passing through the liquid. The light is dispersed due to the presence of particles suspended within the medium under analysis. The way in which light is dispersed in the medium is related to the size, shape, composition of the particles in the suspension and the wavelength of the incident light on the sample.
How is turbidity measured?
Turbidity is a measure of the degree to which water loses its transparency due to the presence of suspended particles, the greater the amount of suspended solids the greater the degree of turbidity. The equipment associated with this measurement is called a turbidimeter, which is the instrument commonly used to measure particles suspended in a liquid, or in a dissolved gas. Turbidity is measured by detecting and quantifying the light dispersion in a solution, and quantified in nephelometric turbidity units. The turbidimeter shows the values measured in NTU (Nephelometric Turbidity Unit).
Turbidimeter accuracy for reliable measurement
Accuracy is the ability of an instrument to give the same result in different measurements under the same conditions. It allows full adjustment or fidelity of a measurement and can be expressed as a range, over the true value, in which a measurement occurs (i.e. ±0.5 ppm). The following characteristics must be considered in order for the instrument to be of good precision:
- Limit of detection: defined as the minimum concentration of a substance that can be measured and reported with 99% confidence that the concentration of the analyte is greater than zero and determined from the analysis of a sample in a given matrix containing the analyte.
- Repeatability: Repeatability is the accuracy within the execution of a data set.
- Data reproducibility: is the accuracy between runs of data sets.
- Calibration: This is the process of grading exactly one device or instrument according to a unit of measurement. Calibration is considered a single run or data set.
- Calibration Verification: This is the process by which the calibration level of the equipment is verified by comparison with a standard unit of measurement.
- Resolution: is the smallest perceptible difference between two measurements that can be made, this is usually the number of decimal places, i.e. 0.01. The resolution changes a lot with the concentration or measuring range of the instrument.
At KALSTEIN we offer quality measuring instruments, such as turbidimeters designed specifically to meet procedures that require high measurement accuracy. For PURCHASE, SALE, or PRICE information, contact us on our website: HERE