Technical Glossary and Key Terminology for the YR06672 Automatic Electric Steam Generator
The YR06672 Automatic Electric Steam Generator serves as a pivotal solution in various industrial applications, particularly in laboratories. Understanding its technical terms and key terminology is essential for optimal operation and maintenance.
Overview of the YR06672 Steam Generator
The YR06672 is engineered to meet strict national standards (GB / T10393-2002) and is specifically designed for efficient steam generation via electric heating technology. This equipment finds utility in research laboratories, pilot plants, and industrial processes that involve the use of rotary evaporators or systems requiring precise thermal control.
Technical Specifications of YR06672
Parameter | Characteristics |
Model | YR06672 |
Power (KW) | 48 |
Evaporation Capacity (KG) | 65 |
Design Temperature (°C) | 150 |
Voltage (V) | 380 |
Operating Pressure (Mpa) | 0.4 |
Water Volume (KG) | 28 |
Steam Pipe Diameter (mm) | DN15 |
Dimensions (cm) | 50 x 65 x 105 |
Gross Weight | 90 kg |
Manufacturing Standard | GB / T10393-2002 |
Steam Humidity | ≤ 2% |
Connection Type | Flange |
Key Technical Terms Related to YR06672
| Term | Definition |
|---|---|
| Automatic Electric Steam Generator | A device that generates steam using electric heating, automating the steam production process. |
| Evaporation Capacity | The maximum amount of water that can be converted to steam per hour, expressed in kilograms. |
| Operating Pressure | The pressure at which the steam generator operates, measured in megapascals (Mpa). |
| Flange Connection | A method of joining pipes using flanges, allowing for easy installation and maintenance. |
| Steam Humidity | The amount of moisture present in the steam, expressed as a percentage. |
| Design Temperature | The maximum temperature that the generator is designed to reach during operation. |
| Power Output | The amount of electrical power consumed by the steam generator, measured in kilowatts (KW). |
| Steam Pipe Diameter | The internal diameter of the pipe used for transporting steam, measured in millimeters. |
| Water Volume | The amount of water the generator can hold, typically measured in kilograms. |
| Efficiency | The ratio of useful output to the total input, usually expressed as a percentage. |
Frequently Asked Questions
What is the importance of steam humidity in the YR06672?
Steam humidity is important because it affects the quality of the steam produced. The YR06672 aims for a humidity level of ≤2%, ensuring that the generated steam is dry and suitable for precise applications in laboratories and industrial processes.
How does the power output affect the performance of the YR06672?
The power output of 48 KW allows the YR06672 to generate significant steam quickly, making it ideal for applications that require rapid heating and evaporation. Higher power output translates to faster operational efficiency and reduced wait times.
What are the advantages of flange connections in the YR06672?
Flange connections simplify the installation, maintenance, and replacement processes. They allow for easy disassembly without damaging the pipes, thereby reducing downtime and service costs.
How can I ensure optimal operating pressure for the YR06672?
To ensure optimal operating pressure, regular monitoring of the pressure gauge is essential. Make sure to maintain the system according to the specified pressure range of 0.4 Mpa, and conduct routine checks for leaks or blockages in the system.
What applications is the YR06672 best suited for?
The YR06672 is best suited for applications in research laboratories, chemical and pharmaceutical industries, as well as processes requiring sterilization and precise thermal control. Its design allows for seamless integration with rotary evaporators and other systems.
What should be considered for site preparation when installing the YR06672?
Site preparation should include ensuring adequate electrical supply (380V), proper ventilation, and sufficient space for installation and maintenance. It is also crucial to check for drainage systems and ensure the area is free from vibrations and electromagnetic interference.
Conclusion
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.
