Kalstein

Automatic Nucleic Acid Extractor YR01869-2

SKU:YR01869-2 · Przez Kalstein

Kategoria:PCR Thermal Cyclers

Automatic Nucleic Acid Extractor YR01869-2

Automatic Nucleic Acid Extractor YR01869-2 — equipo de laboratorio Kalstein con especificaciones técnicas, características avanzadas y soluciones profesionales certificadas para uso científico.

The Automatic Nucleic Acid Extractor YR01869-2 is a state-of-the-art equipment specifically designed to streamline and enhance the nucleic acid extraction process. Leveraging the advanced Rotary Mixing Technology (RMT), this device offers unmatched efficiency by allowing the simultaneous extraction of multiple samples without cross-interference. Its compact and user-friendly design, equipped with a 6.86-inch touch screen and remote control capability via a smartphone or tablet, makes it a versatile tool for laboratories with varied assay needs, solidifying its position as an industry favorite and a recipient of the prestigious Red Dot Design Award 2021.

Market Price

The Automatic Nucleic Acid Extractor YR01869-2 falls within the price range of approximately $8,800 to $9,600 USD, reflecting its advanced capabilities and cutting-edge design. This equipment represents a significant investment for laboratories seeking to enhance their operational efficiency and precision in nucleic acid extraction. To receive a tailored quotation and explore exclusive offers, including specialized technical support, we invite you to generate an automatic quotation through the Kalstein Plus platform to capitalize on the full potential of this major technological investment.

Frequently Asked Questions

  • What types of samples can be processed with the Automatic Nucleic Acid Extractor YR01869-2? This extractor is designed to handle a diverse range of samples, particularly those requiring meticulous nucleic acid extraction for DNA and RNA analysis.
  • Is the YR01869-2 easy to operate? Absolutely, it features an intuitive 6.86-inch touch screen along with a remote control system accessible via smartphones or tablets, simplifying its operation meaningfully.
  • How should I maintain the device to ensure optimal performance? It is crucial to clean the device after each use and keep its system updated remotely to ensure it operates at peak efficiency.

Advantages and Disadvantages

Advantages:

  • High Flexibility: Capable of managing multiple projects simultaneously with varied yields.
  • Automated Workflow: The device's ability to automatically identify reagents and perform remote updates reduces manual intervention, boosting overall efficiency.
  • Advanced Protection System: Incorporates UV lamps, negative pressure, and HEPA filtration to minimize contamination risks and ensure precise results.
  • Compact and Portable Design: Designed for mobility, this device allows experimentation in various settings, making it highly adaptable for different applications.

Disadvantages:

  • High Price: Though it offers considerable value for high performance, the cost may pose challenges for smaller laboratories with constrained budgets.
  • Requires Specialized Maintenance: As with any sophisticated device, trained personnel are necessary for maintenance and system updates.

Product Use in the Field

The Automatic Nucleic Acid Extractor YR01869-2 is predominantly employed in genetic research labs, clinical diagnostic centers, and biotechnology sectors. Its applicability extends to environments like hospitals, forensic labs, and scientific research facilities, where it plays a vital role in nucleic acid extractions, biological sample analysis, and PCR projects. Featuring a mobile power source and a portable design, this extractor is indispensable in scenarios demanding flexible and rapid intervention for immediate results.

Recommendations

To maximize the performance of the Automatic Nucleic Acid Extractor YR01869-2, adherence to manufacturer-recommended maintenance procedures is vital. This includes regular cleaning and updating of reagent protocols. The device is designed for parallel tasking, so utilizing its full capability by running multiple assays concurrently can significantly enhance laboratory productivity. Additionally, utilizing the integrated UV disinfection and HEPA filtration systems is crucial for preventing cross-contamination and ensuring accuracy in results.

Features

  • Advanced Rotary Mixing Technology
  • User-Friendly Interface with Remote Control
  • Compact, Portable Design for Versatile Use
  • Automatic Reagent Identification and Protocol Management
  • Robust Safety Features: UV Lamps, HEPA Filtration
  • Multi-language Support: Chinese/English
  • Real-Time Monitoring and Power Failure Protection

Technical Specifications

ModelYR01869-2
Throughput16
Processing Volume20-1700μL
Sample Processing Volume200-500μL
Compatible ConsumablesCustomized 96-deep-well plates, single 6-strip tubes
Inter-well DifferenceCV≤3%
Mixing MethodRotary mixing
Rotary Speed100~3000rpm
Temperature Control RangeTemperature control separately for lysis and elution.
Temperature range from 30°C to 120°C.
Temperature Control AccuracyHeating speed: 4.0±0.2°C/s.
Temperature accuracy: ±1.0°C.
Temperature uniformity:≤1.0°C.
LanguagesChinese/English
Protocol ManagementFlexible to create, edit and delete protocols
Operation ModeMode 1: Android systems in smartphones/tablets
Mode 2: 6.86 inch full-color LCD screen
Automatic ControlAutomatic opening and closing of the experiment cabin
Reagent IdentificationAutomatic identification of reagent information and running the assays
Mixing Sleeve MonitoringReal-time monitoring of the mixing sleeves status in experiment
Magnetic Bead Residue≤1%
Power Failure ProtectionChoose freely whether or not to continue the experiment when the power is on again after cutting off
DisinfectionOzone + UV disinfection
Auto Power-offAuto power-off after UV disinfection
Negative-Pressure FiltrationNegative pressure HEPA filtration module
Connection Port TypeUSB port
Weight7.4Kg (net)
Instrument Dimensions210mm(L)*229mm(W)*242mm(H)
Power SupplyAC220V, 50Hz

Specyfikacja techniczna

WymiaryL 34 × W 29 × H 31 cm
Waga11 kg
ProducentKalstein

Najczęstsze pytania

Jak poznać ceny Automatic Nucleic Acid Extractor YR01869-2?

Aby poznać cenę Automatic Nucleic Acid Extractor YR01869-2, wyślij nam e-mail za pośrednictwem formularza kontaktowego AQUI.

Jakie są czasy dostawy Automatic Nucleic Acid Extractor YR01869-2?

Czas dostawy zależy od dostępności w magazynie i rodzaju transportu (lotniczy lub morski). W magazynie: lotniczy 15-30 dni, morski 45-60 dni. Poza magazynem: lotniczy 30-60 dni, morski 60-90 dni.

Jak dokonać zakupu Automatic Nucleic Acid Extractor YR01869-2?

Możesz kupić e-mailem ([email protected]), telefonicznie (+33 (0) 1 70 39 26 50) lub przez oficjalną stronę Kalstein w swoim kraju.

Jak działa gwarancja na Automatic Nucleic Acid Extractor YR01869-2?

Wszystkie urządzenia Kalstein objęte są 1-roczną gwarancją na wady produkcyjne. Gwarancja nie obejmuje szkód spowodowanych nieprawidłową instalacją lub użytkowaniem. Zobacz nasze «warunki» AQUI.

Czy mogę poprosić o wycenę online Automatic Nucleic Acid Extractor YR01869-2?

Tak, możesz poprosić o wycenę bezpośrednio na naszej oficjalnej stronie. Kliknij AQUI.