Controlled Atmosphere Muffle Furnace YR06618// YR06621

Controlled Atmosphere Muffle Furnace YR06618// YR06621 — equipo de laboratorio Kalstein con especificaciones técnicas, características avanzadas y soluciones profesionales certificadas para uso científico.
Frequently Asked Questions
What types of atmospheres can the controlled atmosphere muffle furnace handle? It can operate with multiple inert and reactive gases such as nitrogen, argon, oxygen, carbon monoxide, hydrogen, and ammonia, depending on the required process. What is the maximum operating temperature? The maximum design temperature is 1800 °C, with precise PID control and a type-B thermocouple. Does it include a vacuum system? Yes, it includes a single-stage rotary vane vacuum pump, with an option for a dual-stage pump to achieve higher vacuum levels. Is it suitable for continuous industrial use? Yes, its robust design, MoSi₂ heating elements, and air-cooled structure make it suitable for intensive use in both industrial and laboratory settings.Advantages and Disadvantages
Advantages:- Precise temperature and atmosphere control
- Wide range of scientific and industrial applications
- High safety level thanks to its double-layer structure
- Flexible configuration according to process and budget
- Requires trained personnel for gas handling
- Higher initial investment compared to conventional furnaces without atmosphere control
Product Use in the Field
In practice, the controlled atmosphere muffle furnace is used in materials laboratories, R&D centers, pilot plants, and specialized industries where avoiding oxidation or modifying the microstructure of materials is essential. For example, in technical ceramic sintering or semiconductor manufacturing, controlling the internal atmosphere ensures consistent mechanical, electrical, and chemical properties, reducing waste and reprocessing.Recommendations
To maximize furnace performance, it is recommended to carefully select the working gas, perform regular maintenance of the vacuum system, and take advantage of segmented PID programs to optimize thermal cycles. Choosing the appropriate chamber volume from the outset helps avoid unnecessary energy costs and improves process efficiency. Many users also choose to integrate the furnace with monitoring systems via RS485 or USB, facilitating traceability and quality control.Technical Specifications
| Model | YR06618 | YR06619 | YR06620 | YR06621 |
| Max. Design Temperature (°C) | 1800 | 1800 | 1800 | 1800 |
| Internal Dimensions | 100 × 100 × 100 | 200 × 150 × 150 | 300 × 200 × 200 | 400 × 300 × 300 |
| (D × W × H) mm | ||||
| Power (kW) | 2 kW | 4 kW | 9 kW | 16 kW |
| Voltage (V) | 220V, 1P | 220V, 1P | 380V, 2P | 380V, 2P |
| Chamber Volume (liters) | 1 | 4.5 | 12 | 16 |
| Max. Vacuum | -0.1 MPa | -0.1 MPa | -0.1 MPa | -0.1 MPa |
| Heating Rate | 0–10 °C/min | 0–10 °C/min | 0–10 °C/min | 0–10 °C/min |
| Heating Element | High-quality MoSi₂ heating elements | |||
| Temperature Accuracy | ±1 °C | ±1 °C | ±1 °C | ±1 °C |
| Furnace Structure | Double-layer air-cooled structure, surface temperature below 60 °C | |||
| Temperature Controller | Intelligent PID temperature controller, 30 programmable segments, SSR control, PID auto-tuning; programmable heating, holding, and cooling | |||
| Atmosphere | Various inert gases such as oxygen, carbon monoxide, nitrogen, argon, etc. | |||
| Gas Control | One or more gas inlets optional, each equipped with a ball valve and connected to a vacuum gauge. Gas outlet connected to an exhaust port; all ports equipped with ball valves. Maximum positive pressure inside the furnace ≤ 0.02 MPa | |||
| Vacuum System | Single-stage rotary vane vacuum pump | |||
| Vacuum Limit | Max. 5 Pa | |||
| Optional Vacuum Pump | Dual-stage rotary vane vacuum pump | |||
| Sealing Method | Furnace door with precision grinding and milling; embedded silicone sealing strip for excellent sealing performance and easy opening/closing | |||
| Standard Accessories: | ||||
| Vacuum pump | Spare heating element | Heat-resistant gloves | Crucible tongs | Thermocouple | Oven door lock | User manual | Tools | ||||
| Certification: CE, ISO, SGS, etc., more than 30 patent certifications | ||||
| Warranty: One-year warranty (excluding wear parts) and long-term technical support | ||||
| Optional: | ||||
| Different chamber sizes to choose from; | ||||
| 50-segment program to choose from; | ||||
| LCD touchscreen control to choose from; | ||||
| RS485/USB port for computer connection to choose from; | ||||
| Working temperature, maximum vacuum to choose from | ||||
Specyfikacja techniczna
| Producent | Kalstein |
|---|
Najczęstsze pytania
Jak poznać ceny Controlled Atmosphere Muffle Furnace YR06618// YR06621?
Aby poznać cenę Controlled Atmosphere Muffle Furnace YR06618// YR06621, wyślij nam e-mail za pośrednictwem formularza kontaktowego AQUI.
Jakie są czasy dostawy Controlled Atmosphere Muffle Furnace YR06618// YR06621?
Czas dostawy zależy od dostępności w magazynie i rodzaju transportu (lotniczy lub morski). W magazynie: lotniczy 15-30 dni, morski 45-60 dni. Poza magazynem: lotniczy 30-60 dni, morski 60-90 dni.
Jak dokonać zakupu Controlled Atmosphere Muffle Furnace YR06618// YR06621?
Możesz kupić e-mailem ([email protected]), telefonicznie (+33 (0) 1 70 39 26 50) lub przez oficjalną stronę Kalstein w swoim kraju.
Jak działa gwarancja na Controlled Atmosphere Muffle Furnace YR06618// YR06621?
Wszystkie urządzenia Kalstein objęte są 1-roczną gwarancją na wady produkcyjne. Gwarancja nie obejmuje szkód spowodowanych nieprawidłową instalacją lub użytkowaniem. Zobacz nasze «warunki» AQUI.
Czy mogę poprosić o wycenę online Controlled Atmosphere Muffle Furnace YR06618// YR06621?
Tak, możesz poprosić o wycenę bezpośrednio na naszej oficjalnej stronie. Kliknij AQUI.