Customization and Advanced Configurations of YR02195: Your Comprehensive Guide
The YR02195 is an advanced infant bilirubin phototherapy unit that allows for significant customization and configuration based on the needs of healthcare providers. This article delves into the various options available to optimize the performance of the YR02195 for clinical use.
Technical Specifications of YR02195
| Specification | Details |
|---|---|
| Model | YR02195 |
| Input Power | <150 VA |
| Light Source | Blue Tube |
| Effective Life of Light Source | 1000 hours |
| Wavelength | 400-550 nm |
| Irradiance Treatment Distance | 10~500 px |
| Effective Area | 1125 px × 600 px |
| Infrared Radiation in Effective Area | ≤10 mW/cm² (760 nm < λ ≤ 1400 nm) |
| Ultraviolet Radiation in Effective Area | ≤1.0 × 10⁻⁵ mW/cm² (180 nm < λ ≤ 400 nm) |
| Operating Noise | ≤55 dB(A) (ambient noise lower than 40 dB(A)) |
| Basic Performance | ≥500 μW/cm² |
| Adjust Angle | 30°, 60°, 90° |
| Adjust Height | 1100 mm ~ 1500 mm |
Customizing Your YR02195 for Specific Therapeutic Needs
The YR02195 unit is designed to meet various therapeutic requirements for treating neonatal jaundice. Customization can be achieved through:
- Adjustable Height: The unit allows for height adjustments between 1100 mm to 1500 mm to accommodate different incubator designs and healthcare professional preferences.
- Adjustable Angles: Operators can modify the angle of the light source (30°, 60°, 90°) to optimize exposure to the infant’s skin and maximize therapeutic efficacy.
Optional Accessories for Enhanced Functionality
To improve the versatility of the YR02195, multiple optional accessories can be integrated:
- Add-on Light Filters: These filters enhance the therapeutic effectiveness by ensuring more targeted light wavelengths reach the infant.
- Mobile Stand: A robust mobile stand allows for flexibility in positioning the unit in various clinical settings.
- Protective Covers: These are important for maintaining hygiene and protecting sensitive components from environmental factors.
Advanced Configurations for Power Users
Power users can take advantage of advanced configurations that allow for:
- Timer Settings: The integrated digital LED timer provides accurate therapy duration tracking along with total time display to ensure compliance with therapy protocols.
- Maintenance Alerts: Custom alerts for lamp changes or maintenance schedules can be set up to ensure optimal functionality of the unit over time.
Clinical Applications and Use Cases
The YR02195 is applicable in various clinical settings, including:
- Neonatal Intensive Care Units (NICUs): It’s crucial for managing hyperbilirubinemia in newborns, with customizable settings enabling tailored treatment plans.
- Well-Baby Nurseries: The unit can be configured for standard procedures during routine check-ups, promoting early detection and treatment of jaundice.
Frequently Asked Questions
What are the key features of the YR02195 that support customization?
The YR02195 features adjustable height and angles, which allow healthcare professionals to adapt the unit to fit the specific needs of the infant, while its digital timer ensures precise monitoring of therapy duration.
How can I enhance the functionality of the YR02195 with optional accessories?
Optional accessories like add-on light filters, a mobile stand, and protective covers can significantly enhance the functionality of the YR02195, allowing for improved therapeutic outcomes and adaptability in various clinical environments.
What advanced configurations are available for the YR02195?
Advanced configurations include customizable timer settings for therapy duration and maintenance alerts for lamp changes, helping to ensure the unit operates efficiently and effectively.
Can the YR02195 be used in NICUs?
Yes, the YR02195 is specifically designed for use in NICUs, as its customizable settings allow for tailored treatment of newborns with hyperbilirubinemia.
What measures are in place to ensure the YR02195 remains effective over time?
Regular maintenance, including lamp changes as indicated by alerts, and adherence to operational guidelines help maintain the effectiveness of the YR02195 unit over time.
What are the recommended usage protocols for the YR02195?
Usage protocols for the YR02195 should include thorough training for operators, adherence to timer settings, and regular assessments of the infant’s response to therapy.
How can I request a quote for the YR02195?
You can request a quote by contacting us directly or through our official channels, ensuring you receive the best pricing for your healthcare facility needs.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.